From this window, click on the DEV selection on the tree to the left of the window as shown below. Any time you select a different PLC Protocol than the one already displayed, the Warning Message shown below will pop up.
Click Yes to accept and the Fields for the selected Protocol will be displayed as shown on the figure below. From the Panel Manager window shown above, configure each field as follows:. Only use a different Number if trying to go through or a Router or if instructed so by your Local Network Administrator. This type of connection is also known as a Pass Through Connection. Related Topics. From the Channel Configuration window shown below, choose the Channel 0 tab. From this Configuration window, make the following field selections and inputs: For the Driver field, click on the down arrow and select DF1 Full Duplex.
Leave all remaining settings as default and click the OK button. This needs to be turned Off as shown above. Table 4. To configure the E-mail From String, initiate a message with a string element as the data. Create your message logic using whatever conditional instructions you may need. Descriptions of each function can be Parameters found following the table. If your network is not divided into subnets, then leave the subnet mask at the default or allow the ENI Configuration Utility to assign a default.
A Security Mask of The ENI sends all e-mail requests to this server, which then sends the e-mail message to the destination. Page 46 Peer-to-Peer Messaging The table below illustrates the relationship between messages and their corresponding configuration addresses. Table 5. For data, two sets of addresses are used as illustrated in the Destination Controller table below.
Page 49 Peer-to-Peer Messaging Open the message instruction and enter the appropriate variables. The variables are described in Table 5. Data Table Address Use any valid file.
This provides an extremely versatile mechanism to report alarms, status, and other data-related functions. To store a destination address, write a message to a specific node number nodes to Node 51 Node The data within the message is sent to Node 51 and forwarded to the e-mail address stored at Node To send e-mail, two sets of addresses are used Message as illustrated in the table below.
Node numbers to are used to define or store the actual e-mail address, and nodes 50 to 99 are used to send the string element to the e-mail recipient. Page 56 E-Mail Messages Node 50 to 99 2. The variables are described in Table 6. Table 6. If your Ethernet network is isolated from the company-wide network, any valid IP Information addresses may be used.
If your Ethernet hub is connected to a larger Ethernet network, contact your System Administrator for unique IP addresses. The first task is to configure the ENI module that will be connected to the computer.
Page 61 Connecting L20 CompactLogix Controllers on Ethernet For this example, we will be using baud on all serial connections. This will download your configuration parameters to ENI 1 and save it to non-volatile memory. In this example, we arbitrarily used Destn address 2 to represent IP address Following the Controllers ladder program are four additional screens showing the two tabs for each MSG Instruction. Following the ladder program are four additional screens showing the two tabs for each MSG Instruction.
Your mapped table for your program should look like the following: Figure 7. Description Color State Indicates A full listing of error codes that may be generated by the Message the ENI Instruction is shown below. Error Code Description of Error Condition Target node cannot respond because of incorrect command parameters or unsupported command. Target or Local Bridge address is higher than the maximum node address. Local service is not supported.
Broadcast is not supported. Learn more about our Product Compatibility and Migration Solutions. Find recommended technical specifications, installation instructions and manuals, organized by product family. Browse Tech Doc Center. Search Literature Library. Get Answers. MicroLogix Communication Modules.