Component damage may result if ESD control procedures are not followed. If you are not familiar with static control procedures, refer to Rockwell Automation publication Rockwell Automation The National Electrical Code and any other governing regional or local code will take precedence. Rockwell Automation cannot assume responsibility for the compliance or proper installation of the side mount module or associated equipment.

Errori di cablaggio o di altro tipo, come l'applicazione di un voltaggio inadeguato o l'utilizzo o lo stoccaggio del prodotto in ambienti con temperature eccessive, possono determinare il malfunzionamento del prodotto.

Welcome to ManualMachine. We have sent a verification link to to complete your registration. Log In Sign Up. Forgot password? Enter your email address and check your inbox. Please check your email for further instructions.

Enter a new password. Rockwell Automation. You can only view or download manuals with. Sign Up and get 5 for free. It is adjustable from 0.

Parameter 21, Jam Warn Level, allows the installer to define the current at which the DeviceNet Module will indicate a warning. Once the Jam Inhibit Time has expired, the Jam.

Motor current less than a specific level may indicate a mechanical malfunction in the installation, such as a torn conveyor belt, damaged fan blade, broken shaft, or worn tool. Such conditions may not harm the motor, however, rapid detection may help to minimize equipment damage and loss of production. The following parameters are available for configuring the DeviceNet Module's underload warning performance:. Once the UL Inhibit Time has expired, the. Rapid communication fault detection helps minimize potential damage due to uncontrolled or unmonitored applications.

When the Comm Fault warning conditions are satisfied, the following will occur:. When a programmable controller is placed into the program mode, the execution of its ladder program is suspended, and any connected networks go to an idle state. Rapid communication idle detection helps minimize the potential damage due to uncontrolled or unmonitored applications.

Choose the appropriate DeviceNet PC interface. In this example, a PCD module is chosen. RSNetWorx notifies the user to upload or download devices before viewing configuration. Select OK. RSNetWorx now browses the network and displays all of the nodes it has detected on the network.

If the screen appears like the following example, continue with. Note : You can download the EDS file from www. Select Register Device from the menu that appears. The EDS Wizard will appear. Select Next. The following screen appears:. Optional Do the following:. Next to the selected Polled check box, do the following:. To display the icon options for the node, select Next.

Select the E1 Plus Overload Relay icon by highlighting it and clicking. After selecting the desired icon, select OK. When prompted to register this device, select Next.

Select Finish. From the Tools menu at the top of the screen, select Node Commissioning. Select Browse. Select the E1 Plus Overload Relay located at node Do not change the baud rate setting, unless you are sure it must be changed.

Type the node address that you want in the New Device Settings section. In this example, the new node address is 5. To apply the new node address, select Apply. When the new node address has been successfully applied, the Current Device Settings section of the window is updated see the example below. If an error occurs, check to see if the device is properly powered up and connected to the network.

To exit the node commissioning tool, select Close. These values determine the amount and arrangement of the information communicated to the master scanner. The consumed information is generally used to command the state of the slave device's outputs, and produced information typically contains the state of the inputs and the current fault status of the slave device. The default Consumed and Produced Assemblies are shown below.

Each assembly has a given size in bytes. This instance number is written to the Input Assembly and Output Assembly parameters. The Automap feature available in all Rockwell Automation scanners automatically maps the information. The following screen Figure 3. Welcome to ManualMachine. We have sent a verification link to to complete your registration. Log In Sign Up. Forgot password? Enter your email address and check your inbox.

Please check your email for further instructions. Enter a new password. Rockwell Automation. Important User Information Solid state equipment has operational characteristics differing from those of electromechanical equipment. Because of this difference, and also because of the wide variety of uses for solid state equipment, all persons responsible for applying this equipment must satisfy themselves that each intended application of this equipment is acceptable.

Because of the many variables and requirements associated with any particular installation, Rockwell Automation, Inc. Reproduction of the contents of this manual, in whole or in part, without written permission of Rockwell Automation, Inc. Throughout this manual, when necessary we use notes to make you aware of safety considerations. Identifies information about practices or circumstances that can WARNING cause an explosion in a hazardous environment, which may lead to personal injury or death, property damage, or economic loss.

Labels may be located on or inside the equipment e. Chapter 1 — Installation and Wiring Chapte. A-1 Electronic Data Sheets. Chapter 1 Installation and Wiring.

Install in suitable enclosure. Keep free from contaminants. Static control precautions are required when installing, testing, servicing, or repairing this assembly.

Component damage may result if ESD control procedures are not followed. If you are not familiar with static control procedures, refer to Rockwell Automation publication The National Electrical Code and any other governing regional or local code will take precedence. Rockwell Automation cannot assume responsibility for the compliance or proper installation of the side mount module or associated equipment. This is a Class A product. Installation and Wiring Figure 1. Figure 1. Table 1. Chapter 2 Protection Functions.

On power-up, it assumes that the E1 Plus Overload Relay is in a non-tripped condition. Parameters 40 and 41 are used to configure the assignment of the inputs. Trip and Warning Enable Parameter 12, Trip Enable , allows the installer to enable or disable the jam trip protective function. This may result in an unintended actuation of controlled industrial equipment, with the potential for machine damage or serious injury to personnel.

Protection Functions If the screen appears like the following example, continue with Building and Registering an EDS file. Figure 3. Do the following to build and register the EDS file: 1. DeviceNet Node Commissioning Figure 3. DeviceNet Node Commissioning 3. Table 3.

DeviceNet Node Commissioning Table 3. Mapping to the Scanner's Scan List The Automap feature available in all Rockwell Automation scanners automatically maps the information.

You can only view or download manuals with.